Product Information
Inside the Box
- Non-return flap
PUR 98 D
- Subject to technical changes; no liability accepted for the accuracy of the information given.
Product Information
Inside the Box
- Non-return flap
Your advantages
Stainless-steel grease filters (10-layer)
Easy to use and effective against grease
Miele CleanCover
Convenience and safety in detail
Safety turn off
Always on the safe side
Stainless-steel grease filters (10-layer)
Easy to use and effective against grease
Miele CleanCover
Convenience and safety in detail
Product data sheet
Island ventilation hood | • |
Recirculated mode | Convertible |
Recirculation conversion kit (order separately) | DUI 32 |
OdorFree charcoal filter (order separately) | DKF 12-P |
Color | Stainless steel |
Electronic controls | • |
Power levels (number excl. Intensive) | 3 |
Programmable Intensive switch-off | • |
Easy-to-clean CleanCover hood liner | • |
Number of dishwasher-safe stainless-steel grease filters | 3 |
LED ClearView lighting | • |
Number x W | 4 x 3 W |
Light intensity in Lx | 500 lx |
Color temperature in K | 3000 Kelvin |
Dual-action blower | • |
AC motor | • |
Air throughput | Values upon request |
Safety shut-off | • |
38 1/4 (970)–50 (1270) | |
40 5/8 (1030)–52 7/8 (1340) | |
Overall min. height for vented and external in in. (mm) | 38 1/4 (970) |
Overall max. height for vented and external in in. (mm) | 50 (1270) |
Overall min. height for recirculation in in. (mm) | 40 5/8 (1030) |
Overall max. height for recirculation in in. (mm) | 52 7/8 (1340) |
Canopy width in in. (mm) | 35 3/8 (898) |
Canopy height in in. (mm) | 2 7/8 (70) |
Depth of hood canopy in in. (mm) | 23 5/8 (598) |
Minimum distance above electric cooktops in in. (mm) | 24 1/8 (610) |
Minimum height above gas cooktop (max. 12.6 kW total power, burner ≤ 4.5 kW) in mm | 26 (660) |
Net weight in lbs. (kg) | 75 (34.0) |
Length of electrical wire in ft. (m) | 0 (0.0) |
Hard-wired | • |
Total connected load in kW | 0.36 |
Voltage in V | 120 |
Fuse rating in A | 15 |
Frequency in Hz | 60 |
Number of phases | 1 |
Vent connection at top | • |
Diameter of vent connection in in. (mm) | 6 (150) |
Telescopic chimney | • |
Optional products and accessories
- Product sheetPDF
- Warranty conditionsPDF
- Operating and Installation instructionsPDF
Follow the link and you will find all the resources you need for planning and installing any of our products
- fbxZIP
- ifcZIP
- dwgZIP
- rvtZIP
- rfaZIP
Follow the link and you will find all the resources you need for planning and installing any of our products

PUR 98 D (Installation drawing) - USA/CDN
1) Installation area/site
2) Vented
3) Recirculation
4) Installation alternatively with spacer frame
5) Ventilation grille positioned at the top for recirculation
6) A supply lead
and for vented mode flexible vent ducting
must be pre-fitted for the connection in the ceiling to the connection of the cooker hood.
- Subject to technical changes; no liability accepted for the accuracy of the information given.