Support for yourSteam Oven

Fault F10

Fault F10 is shown on the display of the steam oven/combi-steam oven. Water inlet fault.

The steam oven has not been used for a very long time. This has caused the feed pump to dry out.

Please contact Miele Customer Service.

The black suction hose in the water container is missing or is not secure; see figure.

Reattach the suction hose.

If the suction hose is missing, leaking, or faulty (e.g., cracks), the suction hose must be replaced.

Please contact Miele Customer Service.

You use an osmosis system in your home.

If an osmosis system is in operation, it may reduce the conductivity of the water. The water hardness must be at least 1 gpg/1 °dH (= 30 µS per cm = 15 ppm). If the conductivity of the water is too low, the electrode in the steam generator will not detect the water.  F10 (no level) is displayed.

Check whether the osmosis system can be switched off.

Add a pinch of salt to the water in the water container to increase the conductivity.

Manual finder

Manual finder

Here you will find the operating instructions for your Miele appliances.
Find your manual
Book a technician

Book a technician

We will happily take your repair booking online.
Schedule a service call
Support 24/7

Support 24/7

Use our contact form to describe your request. Miele Service will get back to you as soon as possible.
Contact us